Ariston PH640MT NG Spécifications Page 34

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 33
6 720 608 782
34
Maintenance and service
To select fan speed:
B Press ON/OFF button into OFF.
B Press and hold "Program" button and press
ON/OFF button to turn appliance ON.
Fig. 57
B As soon as '188' is displayed, release "Program"
button , and the display should read P2.
B Press or to choose the fan speed suitable
with your installation, see Table 19.
B Press and hold (± 5 sec.) “Program” button until
the display flashes, then the selected value is
memorized.
Mode Pipe Length
1)
1) Full equivalent length (inlet+outlet+fittings). Do not
count terminals and first elbow used on intake and
exhaust.
Fan speed
“P2”
for 3 ft up to 19 ft 6
for 20 ft until 46 ft 7
for 47 ft until 52 ft 8
Table 19Fan speed adjustment
Vue de la page 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 55 56

Commentaires sur ces manuels

Pas de commentaire