Ariston C Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Chauffe-eau et chaudières Ariston C. Ariston C User`s manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1

UsersManual

Page 2

IGNITION PROCEDURETurn the selector knob “A” to the “J”position. The green L.E.D. “D” willilluminate indicating that the boiler isready to operate. Th

Page 3

the user can select winter or summeroperating mode. Keeping the knob “C”at the “0” position selects the summeroperating mode. Winter operatingmode may

Page 4 - 1. GENERAL INFORMATION

12it at max in order toobtain the bestperformance fromthe boiler and toallow the regulationof the externaltemperature tofunction efficiently.SETTING T

Page 5 - TECHNICAL INFORMATION

13The comfort mode is a specialoperating state, because the watercontained in the secondary exchangerand in the primary exchanger is kept ina preheate

Page 6 - 23/27 MFFI

143. USEFUL INFORMATION AND TROUBLESHOOTINGBOILER SHUTDOWN SITUATIONSThe boiler is equipped with safetydevices that intervene in certainsituations and

Page 7

15SHUTDOWN DUE TO INSUFFICIENTWATER CIRCULATIONIf the red L.E.D. “L” isilluminated and theboiler is off, onepossible cause for thisstate is an insuffi

Page 8 - HELPFUL SUGGESTIONS

IMPORTANT!If this situation occurs frequently,contact an Authorised Service Centre.so that they may check that the exhaustfumes are being expelled cor

Page 9 - PRACTICAL TIPS

176. TIME CLOCKNOTE: the time clock is for centralheating control only.The time clock is provided with 96switches, called riders, each of whichcovers

Page 10 - WINTER AND SUMMER

18clock border;- pull outward the riders for 7.00 amand 9.30 am, and then all ridersbetween these two;- repeat this for 7.00 pm and 10.00pm.Other heat

Page 11 - EXTERNAL (ROOM) THERMOSTAT

19TECHNICAL DATAAmbient temperature:- 10°C to + 55°CRunningreserve:150 h (not for 1.5 V DC)Shortestswitching time: 15 minutesProgrammable: Every 15 mi

Page 12 - ECONOMY/COMFORT MODE

2Dear Customer,Thank you for choosing an ARISTONboiler.We guarantee that your boiler is a reliableand technically sound product.This User's Manua

Page 13 - TURNING OFF THE BOILER

20Cod. 2399841468112 - Stampa: Bieffe RecanatiManufacturer: Merloni TermoSanitari SpA - ItalyCommercial subsidiary: MTS (GB) LIMITEDMTS BuildingHughe

Page 14 - 3. USEFUL INFORMATION

3TABLE OF CONTENTS1. GENERAL INFORMATION page 4Technical Information page 5Control Panel page 62. OPERATING INSTRUCTIONS page 83. USEFUL INFOR

Page 15 - TEMPORARY SHUTDOWN DUE TO

41. GENERAL INFORMATIONMTS (GB) Limited support theinitiative. Your installer will give you, andshow you how to use, a logbook which willgive you impo

Page 16 - 5. CHANGE OF GAS TYPE

TECHNICAL INFORMATION5GENERAL DATAHeating input max-minHeating output max-minEfficiency at Maximum Thermal Capacity (seeinstallation instructions)CENT

Page 17 - 6. TIME CLOCK

6CONTROL PANEL23/27 MFFIFR025A

Page 18

7LEGEND:A - On/Off knobB - Domestic hot water temperatureadjustment knobC - Central heating selection (winter) and temperature adjustment knobD - On/O

Page 19 - TECHNICAL DATA

82. OPERATING INSTRUCTIONSCAUTIONInstallation, start-up, adjustmentsand maintenance must be performedby a competent person only, inaccordance with the

Page 20 - Stampa: Bieffe Recanati

9value. Consult your installer forchecking and refilling the system.- The outer panels of the unit's casemust only be cleaned with a dampcloth. D